PENGUKURAN DOSIS EFEKTIF ORGAN TYROID DAN MATA PADA PEMERIKSAAN MAMMOGRAFI
DOI:
https://doi.org/10.31958/js.v8i1.437Abstract
A research has been done about the effective dose measurement of thyroid and eye organ on mammography examination. The aims of the research is to determine the radiation dose absorbed by the thyroid organ and eye examination Mammography. This research uses TLD-100 as a radiation measuring instrument. The data retrieval process has taken place in Parahita Laboratorium, Jakarta by collecting five of patients data to have Mammography radiology examination, the research is done by putting the TLD-100 in every side of thyroid organ and eye to know the value radiation dose which occurs in Mammography examination. Eksposi factors used in this study was 29 kV and 250 mA. The result of this research is obtained the value of the dose absorbed by the thyroid organ and less than the limit value of existing dose of 0,7 mSv, To analysts equivalent dose in patients who received organ Mammography is quite safe because less than the value standard dose limits specified.
Key words : mammography, radiation dose, TLDReferences
Sudibjo P. 1996. Anatomi Mata. Samarinda: Gunung Kelud.
Tjokronegoro A. 1982. Imunologi Diagnostik dan Terapi. Depok Jawa Barat : Fakultas Kedokteran Universitas Indonesia.
Pravasani A. 2012. Pengaruh Radioterapi Area Kepala dan Leher Terhadap pH Saliva. Skripsi. Semarang: Fakultas Kedokteran Universitas Diponegoro.
Dewiana. 2012. Analisa Dosis Serap Organ Kritis lensa mata pada terapi karsinoma nasofaring dengan pesawat sinar-X 6mV. Skripsi. Jakarta: Fakultas Teknik dan Sains Universitas Nasional.
Anam C. 2013. Analisis Penerimaan Dosis Radiasi Di Organ Mata Pada Pemeriksaan Nasofaring Menggunakan Ct Scan. Skripsi. Semarang: Fakultas Sains dan Matematika Universitas Diponegoro.
Rudi, et al. 2012. Pengukuran Paparan Radiasi Pesawat Sinar x Di Instalasi Radiodiagnostik Untuk Proteksi Radiasi. Unnes Physics Journal. Unnes Physics 1 (1) (2012). Semarang: Jurusan Fisika FMIPA Universitas Negeri Semarang Gunungpati.
Bushong S. 1988. Radiologic Science For Technologists, fourt edition. Washington : C.V. Mosby company.
PERKA BAPETEN NO 8 2011 Tentang Keselamatan Radiasi dalam penggunaan pesawat Sinar-X Radiologi Diagnostik dan Intervensional.
Akhadi M. 2000. Dasar – Dasar Proteksi Radiasi. Jakarta: Rineka Cipta. 41
Edwards C, Statkiewicz M dan Ritenour E. 1990. Perlindungan Radiasi Bagi Pasien dan Dokter Gigi. Jakarta: Widya Medika.
Krane K. 1992. Fisika Modern. Terjemahan oleh Wospakrik. H.J. Jakarta: Universitas Indonesia.
Beiser A. 1992. Konsep Fisika Modern. Jakarta: Erlangga.
Cember H. 1983. Pengantar Fisika Kesehatan. Edisi. Semarang: IKIP Semarang Press.
Suyati dan Akhadi M. 1998. Mengukur Kualitas Radiasi Keluaran Pesawat SinarX. Buletin Alara. 2(2): 7-12.
Kaplan I. 1979. Nuclear Physics, 2 nd edition. London: Addison-Wesley Publishing Company.
Dhahryan AM. 2009. Pengaruh Teknik Tegangan Tinggi terhadap Entrasce Skin Exposure (ESE) dan Laju Paparan Radiasi Hambur pada Pemeriksaan Abdomen. Berkala Fisika. 12 (1): 21-26.
Compagnone G, Pagan L dan Bergamini C. 2005. Comparison of Six Phantoms for Entrance Skin Dose Evaluation in 11 Standard X-Ray Examinations. Journal of Applied Clinical Medical Physics. 6(1):101-113.
Sharifat, Oyeleke OI. 2009. Patient Entrance Skin Doses at Minna and Ibadan for Common Diagnostic Radiological Examinations. Bayero Journal of Pure and Applied Sciences. 2(1): 1-5.
Waseso. 1998. Pengaruh Variasi Tegangan dan Arus Terhadap Kualitas Radiograf dan Dosis Yang Diterima Pasien pada Pemotretan Paru-Paru Proyeksi Postero Anterior (Study Kasus Di RSPAD “Gatot Soebroto“Jakarta). Skripsi. Semarang :Universitas Dipenegoro. 42.
Fahmi A, Firdausi KS, Budi WS. 2008. Pengaruh Faktor Eksposi pada Pemeriksaan Abdomen terhadap Kualitas Radiograf dan Paparan Radiasi menggunakan Computed Radiography. Berkala Fisika. 11 (4): 109- 118.
Sofyan H, Akhadi M, Prasetio H, Budiantari CT, Nuraeni N. 2012. Uji Karakteristik Dosimeter TL LiF:MG,Cu,P dan Dpsimeter OSL dan Pengembangan Metode Audit Dosimeter Fasilitas Radiologi untuk Peningtkatan Layanan dan Keselamatan Pasien Anak. Jakarta: Batan.
Pearce EC. 2009. Anatomi dan fisiologi untuk Paramedis. Jakarta: PT Gramedia Pustaka Utama.
Downloads
Published
Issue
Section
License
Copyright (c) 2017 Lody Firmansyah

This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
Authors who publish with this journal agree to the following terms:
- Authors retain copyright and grant the journal right of first publication with the work simultaneously licensed under a Creative Commons Attribution License that allows others to share the work with an acknowledgement of the work's authorship and initial publication in this journal.
- Authors are able to enter into separate, additional contractual arrangements for the non-exclusive distribution of the journal's published version of the work (e.g., post it to an institutional repository or publish it in a book), with an acknowledgement of its initial publication in this journal.
- Authors are permitted and encouraged to post their work online (e.g., in institutional repositories or on their website) prior to and during the submission process, as it can lead to productive exchanges, as well as earlier and greater citation of published work.